Repository Universitas Andalas

OPTIMASI PENENTUAN Fe(II) dan Fe(III) SECARA SIMULTAN DENGAN METODA ADSORPTIVE STRIPPING VOLTAMMETRI (AdSV)

Putra, Nanda Rade (2014) OPTIMASI PENENTUAN Fe(II) dan Fe(III) SECARA SIMULTAN DENGAN METODA ADSORPTIVE STRIPPING VOLTAMMETRI (AdSV). Other thesis, Universitas Andalas.

[img]
Preview
PDF
Download (502Kb) | Preview

Abstract

Penelitian mengenai optimasi penentuan Fe(II) dan Fe(III) secara serentak dengan voltammetri stripping adsorptif (AdSV) telah dilakukan. Diteliti konsentrasi kalkon, pH, potensial akumulasi, dan waktu akumulasi optimum sebagai parameter yang dipakai dalam metoda ini. Dari hasil penelitian diperoleh kondisi optimum konsentrasi kalkon 0,6 mM, pH 7, potensial akumulasi -0,6 V dan waktu akumulasi 70 detik. Hasil penentuan standar deviasi relatif diperoleh pada pengukuran larutan standar Fe(II) 10 µg/L, dan Fe(III) 10 µg/L adalah 1,33% untuk Fe(II) dan 3,48 % untuk Fe(III).Hal ini menunjukkan bahwa tingkat ketelitian metoda sudah cukup baik dengan 10 kali pengulangan. Metoda ini diaplikasikan pada 3 sampel Dengan nilai perolehan kembali 98,6% untuk logam Fe(III), dan 0% untuk logam Fe(II). Kata kunci: Besi ,Kalkon, Voltammetri Stripping Adsorptif ABSTRACT OPTIMIZATION OF Fe(II) AND Fe(III) DETERMINATION SIMULTANOUSLY BY ADSORPTIVE VOLTAMETRY STRIPPING (AdSV) by: Nanda Rade Putra (BP : 0910413116) Prof. Dr. Hamzar Suyani, MSc dan Deswati, MS Research about optimization of Fe(II) and Fe(III) determination simultaneously by adsorptive voltammetry stripping (AdSV) has been done. Researched concentration of calcon, pH, potential of accumulation, and optimum time of accumulation as standard used in this method. From the result, optimum condition of kalkon concentration was 0,6 mM, pH 7, potential of accumulation - 0,6 V and time of accumulation was 70 second. The result of relative deviation standard in standard solution of 10 µg/L Fe(II), and 10 µg/L Fe(III) was 1,33% for Fe(II) and 3,48 % for Fe(III). It showed that accuracy level of method was good enough with 10 accuracy. The method was applied in 3 samples with recovery level 98,6% for Fe(III), and 0% for Fe(II). Keywords: Iron, Calcon, Adsorptive Voltammetry Stripping

Item Type: Thesis (Other)
Subjects: Q Science > QD Chemistry
Unit atau Lembaga: Fakultas MIPA > Kimia
Paca Sarjana > Doktor > Fakultas MIPA > Kimia
Fakultas MIPA > Kimia
Depositing User: Riani Tri Utami
Date Deposited: 20 May 2014 01:47
Last Modified: 20 May 2014 01:47
URI: http://repository.unand.ac.id/id/eprint/20064

Actions (login required)

View Item View Item